4 in. [102 mm, D. frame the fireplace, C. sidewalls/surrounds – Hearth and Home Technologies EL36 User Manual

Page 20

Advertising
background image

20

A

Fireplace

Opening

B

Outside

Dimensions

in.

36

41

mm

914

1041

in.

42

47

mm

1067

1194

Model #

EL36

EL42

B

A

9 3/4 in.

[248 mm]

12 in.

[305 mm]

12 in.

[305 mm]

11 1/4 in.

[286 mm]

FLUSH

FRONT

4 in.

[102 mm]

BRICK

FRONT

50° angle

39° angle

D. Frame the Fireplace

Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
• Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.

• Framing across the top of fireplace must be above top standoffs.

B

C

A

2 in. (51 mm)

min. air space

clearance

from chimney.

Header MUST NOT be notched!

D

D = extra space needed for outside air connection.
If outside air duct has no bend, this dimension may be
reduced as long as minimum clearances are met.

Model

A

B*

C**

D

in.

42

21 1/2

39 3/4

8

mm

1067

546

1010

203

in.

48

21 1/2

39 3/4

8

mm

1219

546

1010

203

* If interior of chase will be drywalled, add the thickness to

this measurement.
** Adjust header height for a raised floor under fireplace.

EL36

EL42

Figure 6.4 Framing the Fireplace

C. Sidewalls/Surrounds

• Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the fireplace opening.

• Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed within the gridded area,

Figure 6.3.

Figure 6.3 Mantel Leg or Wall Projections (Acceptable on both sides of opening)

Heatilator • EL36/EL42 • 4044-132 • Rev AD • 7/12