Hearth and Home Technologies EL36 User Manual

Page 23

Advertising
background image

23

Outside Air

Hood

Outside Air

Plate

Assembly

2 Wire Ties

Flexible Duct

(not supplied)

Figure 7.5 Outside Air Installation

E. Install Outside Air Kit

• Optional.

• Keep duct runs short and straight to minimize restriction.

A small dip is acceptable for a cold air trap.

• The outside air kit must be installed on the left hand side

of the fireplace.

• Locate the outside air hood in a clear area, preferably

into prevailing wind during the heating season. Refer to

Figure 5.2.

• Install as shown in Figures 7.3, 7.4 and 7.5.

• The air duct may be run vertically.

• The outside air hood must be at least 3 ft (.91 m) below

the top of the uppermost chimney section.

CAUTION! Risk of Fire or Asphyxiation! DO NOT

draw outside combustion air from wall, floor or ceiling

cavity, or enclosed spaces such as an attic or garage.

DO NOT place outside air hood close to exhaust

vents or chimneys. Fumes or odor could be drawn

into the room through the fireplace.

• Locate outside air inlet to prevent blockage from

leaves, snow/ice, or other debris. Blockages could

cause combustion air starvation.

Heatilator • EL36/EL42 • 4044-132 • Rev AD• 7/12