Warning, G. vertical termination, Step 2. s – Heat & Glo Fireplace VRTIKL-AU User Manual

Page 18: Balanced flue pipe

Advertising
background image

18

Heat & Glo • VRTIKL-AU • 2123-900 • 7/07

STORM COLLAR

PIPE LENGTH

FIRESTOP

VERTICAL
TERMINATION CAP

FLASHING

SUPPORT BOX

11.8M
MAXIMUM

On vertical terminations use only Part #SLK-991DA

Figure 4.20

Step 1.
Check the installation instructions for required 25 mm
clearances (air space) to combustibles when passing
through ceilings, walls, roofs, enclosures, attic rafters, or
other nearby combustible surfaces. (See Figure 4.14).
Check the instructions for maximum vertical rise of the
flueing system, and any maximum horizontal offset limi-
tations. All offsets must fall within the set parameters of
the flue charts (Figure 4.2) located on pages 11-15.

Note: Maximum vertical rise allowable is 11.8 m, Figure 4.2.

WALL
STRAP

TWO 45 DEGREE
ELBOWS

METAL STRAP
CONNECTED TO
WALL STRAP

Step 2.
S

et the gas stove in its desired location. Drop a plumb

bob down from the ceiling to the position of the gas
stove flue exit, and mark the location where the flue will
penetrate the ceiling. Drill a small hole at this point. Next,
drop a plumb bob from the roof to the hole previously
drilled in the ceiling, and mark the spot where the flue will
penetrate the roof. Determine if ceiling joists, roof rafters,
or other framing will obstruct the flueing system. You may
wish to relocate the gas stove, or to offset, as shown in
Figure 4.21 to avoid cutting load bearing members.

1. Balanced Flue Pipe

Figure 4.21

Figure 4.19

G. Vertical Termination

Fire Risk.

Explosion Risk.

Maintain fl ue clearance to combustibles as
specifi ed.

• Do not pack air space with insulation or other

materials.

Failure to keep insulation or other materials
away from fl ue pipe may cause fi re.

WARNING