1. installing welding generator – Hobart Welding Products OM-494 User Manual
Page 18
OM-494 Page 14
SECTION 4 – NSTALLATION
When facing the front panel, the Welder B
controls and weld terminals are on the
right and the Welder A controls and weld terminals are on the left.
NOTE
4-1.
Installing Welding Generator
install1 10/00* – Ref. 800 652 / Ref. 800 477-A / 158 936-A / S-0854
1
2
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
GND/PE
3
4
Y
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
Y
Always securely fasten
welding generator onto
transport vehicle or trailer
and comply with all DOT and
other applicable codes.
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y
Be sure equipment con-
nected to the 240 V recep-
tacles is GFCI-protected.
2
OR
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Airflow Clearance
Location
Grounding
OR
Y
Do Not Lift Unit From End