1. installing welding generator – Hobart Welding Products OM-494 User Manual

Page 18

Advertising
background image

OM-494 Page 14

SECTION 4 – NSTALLATION

When facing the front panel, the Welder B

controls and weld terminals are on the

right and the Welder A controls and weld terminals are on the left.

NOTE

4-1.

Installing Welding Generator

install1 10/00* – Ref. 800 652 / Ref. 800 477-A / 158 936-A / S-0854

1

2

Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.

GND/PE

3

4

Y

Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.

Y

Always securely fasten
welding generator onto
transport vehicle or trailer
and comply with all DOT and
other applicable codes.

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding
Terminal

4

Grounding Cable

Use #10 AWG or larger insulated
copper wire.

Y

Be sure equipment con-
nected to the 240 V recep-
tacles is GFCI-protected.

2

OR

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Grounding

OR

Y

Do Not Lift Unit From End