OM-494 Page 40

7-9.

Inspecting And Cleaning Optional Spark Arrestor Muffler

Ref. 800 633-B / Ref. 190 377

Y

Stop engine and let cool.

1

Spark Arrestor Muffler

2

Cleanout Plug

Remove plug and remove any dirt
covering cleanout hole.

3

Exhaust Pipe

Start engine and run several min-
utes to blow out cleanout hole. If
nothing blows out of hole, briefly
cover end of exhaust pipe with fire-
proof material.

Y

Stop engine and let cool.

Reinstall cleanout plug.

Tools Needed:

3

2