Hobart Welding Products OM-494 User Manual
Page 44
Advertising
OM-494 Page 40
7-9.
Inspecting And Cleaning Optional Spark Arrestor Muffler
Ref. 800 633-B / Ref. 190 377
Y
Stop engine and let cool.
1
Spark Arrestor Muffler
2
Cleanout Plug
Remove plug and remove any dirt
covering cleanout hole.
3
Exhaust Pipe
Start engine and run several min-
utes to blow out cleanout hole. If
nothing blows out of hole, briefly
cover end of exhaust pipe with fire-
proof material.
Y
Stop engine and let cool.
Reinstall cleanout plug.
Tools Needed:
3
2
1
3/8 in
Advertising