maintain a minimum of 12 inches (30.5cm) clearance between the vent hood

and the ground or any other obstruction. The vent flap should be able to move

freely, although vertical orientation of the exhaust system is acceptable. Certain

extenuating circumstances could affect the performance of the dryer:

1. Only rigid metal duct work should be used.
2. Venting vertically through a roof may expose the exhaust system to down

drafts causing an increase in vent restriction.

3. Running the exhaust system through an uninsulatedarea may cause

condensation and faster accumulation of lint.

4. Compression of crimping of the exhaust system will cause an increase in

vent restriction.

The exhaust system should be inspected and cleaned a minimum of every 12

months with normal usage. The more the dryer is used the more often you

should check the exhaust system and vent hood for proper operation.

English

8

RECOMMENDED MAXIMUMM

Exhaust Hood Types

Recommended

Use only for short

run installations

No. of 90º

elbows

Rigid Metal

Flexible Metal

Rigid Metal

Flexible

Metal

0

90 ft.

55 ft.

60 ft.

45 ft.

1

60 ft.

40 ft.

45 ft.

30 ft.

2

45 ft.

30 ft.

35 ft.

20 ft.

3

35 ft.

20 ft.

25 ft.

15 ft.