OM-203 653 Page 15

SECTION 5 − OPERATION

5-1. Controls

1

4

2

3

5

ON

OFF

PRESSURE

60 PSI

5

6

24

27

6

Set To

60 PSI (414 kPa)

20

16

24

27

20

16

1

24

27

20

16

Requires

70-150 PSI

(483-1034 kPa)

Supply

Setting Gas/Air Pressure

1

Output Control

Use control to set cutting output.
Place control in Gas/Air Set position to safely

adjust gas/air pressure. Only gas/air circuit

is activated.
If 22-27 amperes of cutting output is used

with 115 VAC input power, and the overload

protection on the input power circuit fre-

quently opens, either reduce the cutting out-

put and/or the cut time or find more adequate

power (see Section 4-1).
2

Trouble Lights (See Section 6-2)

3

Power Light

4

Power Switch

Setting Gas/Air Pressure
5

Air Filter/Regulator

6

Pressure Adjustment Knob

Place Output control in Gas/Air position and

turn on gas/air supply. Lift knob and turn to

adjust pressure. Push knob down to lock in

setting.
Place Output control in desired cutting

output.

.

At ambient temperatures below −55 C

(235 F), readjustment of gas/air

pressure regulator may be necessary.

Ref. 200 808 / Ref. 802 784