SECTION 6 − OPERATING THE WELDING GENERATOR

If the unit is extremely overloaded, weld and generator power will stop. Turn unit off
and restart to reset the generator protection circuit and restore weld and generator
power output.

If the rated output of the unit is exceeded, engine speed may vary rapidly until the
weld or generator power load is reduced.

NOTE

6-1. Front Panel Controls

Ref. 202 069-C

4

1

3

2

1

Engine Control Switch

Use switch to start engine, select speed, and

stop engine. In Run/Idle position, engine runs

at idle speed at no load, and weld/power

speed under load. In Run position, engine

runs at weld/power speed.
2

Engine Choke Control

Use control to change engine air-fuel mix.

To Start: pull out choke and turn Engine Con-

trol switch to Start position. Release switch

and slowly push choke in when engine starts.

.

If the engine does not start, let the engine
come to a complete stop before attempt-
ing restart.

To Stop: turn Engine Control switch to Off

position.

3

Engine Hour Meter

4

Amperage Control

Use control to select weld amperage. Select

amperage according to electrode being used

(see Section 5-9). Control may be adjusted

while welding. Control does not affect gener-

ator power output.