SECTION 8 − MAINTENANCE (ONAN-POWERED UNITS)

8-1. Routine Maintenance (Onan-Powered Units)

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.

Note

Recycle

engine

fluids.

Y Stop engine before maintaining.

.

See Engine Manual and Maintenance Label for
important start-up, service, and storage informa-
tion. Service engine more often if used in severe
conditions.

*

To be done by Factory Authorized Service Agent.

Every 8 h

Wipe up spills.

Check fluid levels.

See Section 5-2.

20 h

25 h

Check and clean

spark arrestor screen.

See Section 8-5.

Service air

cleaner wrapper

(foam element).

See Section 8-3.

Every 50 h

Clean and

tighten weld

terminals.

Every 100 h

Clean cooling system.

See Engine Manual.

Change oil. See

Section 8-6 and

maintenance label.

Clean and

tighten battery

connections.

Service air

cleaner element.

See Section 8-3.

Every 200 h

Replace fuel

filter. See

Section 8-6.

Change oil filter. See

Section 8-6 and

maintenance label.

Check spark plugs.

Replace

unreadable

labels.