2. Module Installation

Mounting:

Align the mounting pins with the grid holes on the back of the enclosure. With the

mounting pin plungers in the “out” position, press the unit into the grid in the desired

location, secure by pushing the plungers in.

Terminate Incoming Service Lines:

Run twisted pair cable from the telephone company demarcation point to the 110 IDC

labeled “LINE IN” on the SAM-V8M.

110 IDC Termination Procedure

Strip 3 in. of outer jacket from the cable. Place wires into proper slots according to

selected configuration. Starting at the blue-position of the IDC, begin with the white

wire of each pair as you progress to the orange-position on the IDC as shown

below. Press wires into slots with punch tool. Trim excess wire with diagonal

cutter.

Brown

White/Brown

Green

White/Green

Orange

White/Orange

Blue

White/Blue

NOTE: one pair of wires corresponds to

each line from the phone company. (Line

1=blue, Line 2=orange, Line 3=green,

Line 4=brown).