Terminate premise wiring, Alarm interface connection – HomeTech 8-Port Voice Module SAM-V8M User Manual

Page 4

Advertising
background image

Terminate Premise Wiring:

Direct Distribution

Run twisted pair cable from the telephone jacks throughout the premise to the

numbered distribution jacks. Terminate modular 8 position plugs to the horizontal

cables using the 568A wire standard.

Patch Panel Distribution

Run twisted pair cable from the telephone jacks throughout the premise to the 110

IDCs of a SAM-D8 patch panel using the termination procedure above. Connect

the numbered distribution ports of the SAM-V8M to the desired ports of the

SAM-D8 patch panel with 8 conductor patch cords.

Note: The 3” jumper cord must be plugged into the “OUT” & “TEST” ports to provide service to

premise wiring.

Alarm Interface Connection:

The SAM-V8M features a security interface port which may be connected to a security

system; in an emergency situation, the security system can seize telephone service on

LINE 1 when the alarm is activated. Connect 8 conductor cord from alarm dialer to the

“Security RJ31” port on the SAM-V8M.