OM-192 440 Page 11
2-5.
Installing Work Clamp
1
Work Cable
Route cable out front panel opening
from inside.
2
Negative (–/Black) Output
Terminal
Connect cable to terminal.
3
Hardware
4
Work Clamp
Route cable through clamp handle
and secure as shown.
Close door.
Ref. ST-802 285 / Ref. ST-801 566
Tools Needed:
1/2, 3/4 in
2
1
3
4
2-6.
Setting Gun Polarity For Wire Type
Tools Needed:
3/4 in
1
1
Polarity Changeover Label
2
Positive (+/Red) Output
Terminal
3
Negative (–/Black) Output
Terminal
Always read and follow wire
manufacturer’s recommended
polarity.
Close door.
3
2
Ref. ST-801 875