15

3. Charging

⅜ When the battery is connected to the battery charger, charging will commence and

the pilot lamp will light in red. (See Table 2)

NOTE: If the pilot lamp does not light, pull out the plug from the receptacle and

check if the battery is properly mounted.

⅜ When the battery is fully charged, the pilot lamp will blink in red slowly. (At 1-second

intervals) (See Table 2)

(1) Pilot lamp indication

The indications of the pilot lamp will be as shown in Table 2, according to the condition
of the charger or the rechargeable battery.

(2) Regarding the temperature of the rechargeable battery.

The temperatures for rechargeable batteries are as shown in the table below, and
batteries that have become hot should be cooled for a while before being recharged.

Table 2

Indications of the pilot lamp

Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)

Lights continuously

Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)

Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)

■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■

Lights continuously

Malfunction in the
battery or the charger

The battery temperature
is high, making recharg-
ing impossible.

Before
charging

While
charging

Charging
completed

Charging
impossible

Charging
impossible
(UC14YF / UC14YF2 only)

Blinks
(RED)

Lights
(RED)

Blinks
(RED)

Flickers
(RED)

Lights
(GREEN)

Table 3

Recharging of batteries that have become hot

Temperatures at which the battery can be recharged

23°F—104°F (–5°C—40°C)

23°F—140°F (–5°C—60°C)

Rechargeable batteries

EB 9