4 .3 projector management using snmp – Hitachi CP-X267 User Manual

Page 91

Advertising
background image

9

4 . Management with Web browser software

4 .3 Projector Management using SNMP

The SNMP (Simple Network Management Protocol) enables to manage the

projector information, which is a failure or warning status, from the computer on

the network. The SNMP management software will be required on the computer

to use this function.

• It is recommended that SNMP functions be carried out by a network

administrator.

• SNMP management software must be installed on the computer to monitor

the projector via SNMP.

NOTE

SNMP Settings (71)
Configure the following items via a web browser to use SNMP.

Example: If the IP address of the projector is set to 192.168.1.10:

1) Enter

“http://192.168.1.10/” into the address bar of the web browser.

2) Enter the Administrator ID and Password and click

[Logon].

3) Click

[Port Settings] on the main menu.

4) Click

[Enable] check box to open the SNMP Port. Set the IP address to send

the SNMP trap to when a Failure/Warning occurs.

5) Click

[Security Settings] on the main menu.

6) Click

[SNMP] and set the community name on the screen that is displayed.

7) Configure the settings for Trap transmission of Failures/Warnings. Click

[Alert Settings] on the main menu and select the Failure/Warning item to be

configured.

8) Click

[Enable] check box to send out the SNMP trap for Failures/Warnings.

Clear

[Enable] check box when SNMP trap transmission is not required.

9) Click

[Apply] button to save the settings.