Two elbows, Three elbows, Top vent - vertical termination - (continued) – Hearth and Home Technologies 6000GCF-IPI User Manual

Page 27

Advertising
background image

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP • 2110-900 Rev. H • 11/08

27

Figure 7.11

Two Elbows

H

1

V

1

V

2

Three Elbows

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

V

2

Top Vent - Vertical Termination - (continued)

Figure 7.12

V

1

H

1

Maximum

V

2

V

1

+ V

2

Minimum

6 in.

152 mm

3 ft

914 mm

*

*

*

1 ft

305 mm

3 ft

914 mm

*

*

*

2 ft

607 mm

6 ft

1.8 m

*

*

*

4 ft

1.2 m

12 ft

3.7 m

*

*

*

V1 + V2 + H1 = 50 ft (15.2 m) Max.

*No specifi c restrictions on this value EXCEPT

V

1

+ V

2

+ H

1

cannot exceed 50 ft (15.2 m)

V

1

= 6 inches (152 mm) Min.

V

1

H

1

+ H

2

V

2

V

1

+ V

2

Minimum

H

1

+ H

2

Maximum

6 in.

152 mm

3 ft

914 mm

*

*

*

3 ft

914 mm

1 ft

305 mm

3 ft

914 mm

*

*

*

3 ft

914 mm

2 ft

610 mm

6 ft

1.8 m

*

*

*

6 ft

1.8 m

4 ft

1.2 m

12 ft

3.7 m

*

*

*

12 ft

3.7 m

H

1

+ H

2

= 17 ft (5.2 m) Maximum

V

1

+ V

2

+ H

1

+ H

2

= 50 ft (15.2 m) Maximum

V

1

= 6 inches (152 mm) Minimum