A. Wiring Requirements

NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with
National Electric Code
ANSI/NFPA 70-latest edition
or the Canadian Electric
Code CSA C22.1.

• Wire the appliance junction box to 110-120 VAC. This is

required for proper operation of the appliance (Intellifi re
ignition).

• A 110-120 VAC circuit for this product must be protected

with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.

• Low voltage and 110 VAC voltage cannot be shared

within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.

B. Intellifi re Ignition System Wiring

• Wire the appliance junction box to 110 VAC for proper

operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.

• Refer to Figure 12.2, Intellifi re Pilot Ignition (IPI) Wiring

Diagram.

• This appliance is equipped with an Intellifi re control valve

which operates on a 3 volt system.

• Plug the 3-volt AC transformer into the appliance junction

box to supply power to the unit OR install two D cell
batteries (not included) into the battery pack before use.

NOTICE: Batteries should not be placed in the battery
pack while using the transformer. Remove batteries before
using the transformer, and unplug the transformer before
installing the batteries. Battery polarity must be correct or
module damage will occur.

C. Optional Accessories Requirements

• This appliance may be used with a wall switch, wall

mounted thermostat and/or a remote control.

Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.

Position the wall switch in the desired position on the
wall. An assembly of 18 ft of 20 AWG is provided with the
fi replace to connect the wall switch to the appliance.

Instead of the supplied assembly, wire with a length of
25 ft or less and a gauge of 20 AWG through 14 AWG
is acceptable.

The wire needs a jacket with a temperature rating of
140 ºF (60 ºC) or higher. At the appliance connect the
wire to the ON/OFF switch pigtails.