Hobart Welding Products OLYMPIC R-115 User Manual

Page 21

Advertising
background image

OM-193 471 Page 17

2-15. Connection For Lincoln Welding Power Sources With Terminal Strip Connections

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To
Ground In Section 2-9)

Connect remaining leads to
terminal block as follows:

A: 115 VAC/Neutral Lead

B: 115 VAC/Hot Lead

C: No Connection

D: Dry Contact Closure w/Respect
To Terminal E Lead

E: 115 VAC/Contact Closure Lead

.

For welding power sources
requiring dry contact closure,
move lead 38 at terminal block
to terminal D.

Secure strain relief clamp around
cord.

Reinstall and secure wrapper to
unit.

Connect remaining end of cord to
welding power source.

Tools Needed:

1

A

B

C

D

E

2

1/4 in

3

32 (Black)

31 (White)

GND

4 (Orange)

2 (Red)

.

Make ground lead connections
according to Section 2-9 before
following this procedure.

2-16. Connection For AIRCO Welding Power Sources With Two-Prong Twistlock And 115

Volts AC Receptacles

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To
Ground In Section 2-9)

Connect remaining leads to
terminal block as follows:

A: 115 VAC/Neutral Lead

B: 115 VAC/Hot Lead

C: No Connection

D: No Connection

E: 115 VAC/Contact Closure Lead

Secure strain relief clamp around
cord.

Reinstall and secure wrapper to
unit.

Connect remaining end of cord to
welding power source.

Tools Needed:

1/4 in

1

A

B

C

D

E

2

3

.

Make ground lead connections
according to Section 2-9 before
following this procedure.

Advertising