HP STORAGEWORKS SSL1016 User Manual

Page 131

Advertising
background image

Troubleshooting

131

SSL1016 Tape Autoloader Reference Guide

.

Table 14: Error Messages

Error Message

Description

Suggested Repair

00 - 25

General software

flags

■

Power cycle the autoloader and run the Health test.

■

Check HP website for firmware updates.

26

Message Send ID

error

■

Check SCSI Bus cables and terminators.

■

Make sure the host bus adapter is installed,

detected, and configured properly.

■

Power cycle autoloader. Repeat checks after power

cycle.

27

Message bad

■

Check SCSI bus cables and terminators.

■

Make sure the host bus adapter is installed,

detected, and configured properly.

■

Power cycle autoloader. Repeat checks after power

cycle.

28

Message parameter

bad

■

Check host device driver.

■

Make sure the software application is supported,

has the autoloader correctly configured, and has

the latest patches installed.

■

Check SCSI bus cables and terminators.

■

Make sure the host bus adapter is installed,

detected, and configured properly.

■

Power cycle autoloader. Repeat checks after power

cycle.

29

Invalid element

■

Check host device driver.

■

Make sure the software application is supported,

has the autoloader correctly configured, and has

the latest patches installed.

■

Power cycle autoloader. Repeat checks after power

cycle.

Advertising