Maximum link attempts, Attempts (see, Maximum – Honeywell 2020 User Manual

Page 182: Link attempts, B-2) is unsuccessful

Advertising
background image

B - 2

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the image
scanner tries to form a connection with a base unit or PC. During the
connection setup process, the image scanner transmits in order to search for
and connect to a base unit. In order to prevent continuous transmissions that
could interfere with other users of the ISM band, the number of attempts to
connect is limited by this setting. After the maximum number of attempts is
reached, the image scanner will not attempt to reconnect to the base unit.
Pressing the trigger or placing the image scanner in the cradle resets the
attempt count and the image scanner will again try to link to the base unit.
When set to zero, the image scanner will try to link until the Power Time-Out
Timer setting (see

page 3-4

) expires.

Scan the Maximum Link Attempts barcode, then scan the number of attempts
for the setting (from 0-100) from the inside back cover. Scan Save to save the
setting.

Default = 0.

Image scanner
power down due to
Power Time-Out
Timer setting (see

page 3-4

)

Trigger must be pulled or the image scanner must be
placed in the base unit to re-link.
(Note: image scanner re-links on power up, but
powers on due to one of the above actions.)

Image scanner
reset due to
firmware upgrade

Re-link occurs automatically.

Image scanner
reset due to battery
change

Re-link occurs automatically.

Image scanner
placed in different
base unit

Re-link to new base occurs automatically.

Event

Auto Reconnect On

Auto Reconnect Off

Maximum Link Attempts