OM-249 498 Page 19

5-7. Electrical Service Guide

Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These

recommendations are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.

60 Hz Single Phase

Input Voltage (V)

230 Volts AC

115 Volts AC

Input Amperes (A) At Rated Output

24

A 20 ampere

individual branch

circuit

protected by

time-delay fuses

or circuit breaker

is required.

See Section 4-2

Max Recommended Standard Fuse Rating In Amperes

1

Time-Delay Fuses

2

30

Normal Operating Fuses

3

35

Min Input Conductor Size In AWG

4

14

Max Recommended Input Conductor Length In Feet (Meters)

53

(16)

Min Grounding Conductor Size In AWG

4

14

Reference: 2008 National Electrical Code (NEC) (including article 630)

1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.

3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and

above).

4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table

310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.

5-8. Extension Cord Data (Use Shortest Cord Possible)
.

When calculating max. cord length, remember to include conductor length from line disconnect device to input power receptacle.

Input Voltage

Input Power

Phase

Hertz

Conductor Size

Max. Cord Length

115 V

1

60

14 AWG

25 ft (8 m)

115 V

1

60

12 AWG

55 ft (17 m)

115 V

1

60

10 AWG

100 ft (30 m)

230 V

1

60

14 AWG

53 ft (16 m)