Problem

Cause

Correction

HEATING OF SHORTENING SECTION

• Gas valve knob turned to the OFF

• Make sure the gas valve knob is

position

turned to the ON position.

• Blown fuse or tripped

• Reset breaker or replace fuse

circuit breaker at supply

box or control panel

• Blown fuse in PC board

• Replace glass fuse in board

•

Faulty POWER/PUMP switch

•

Check COOK/PUMP switch
per COOK/PUMP Switch Section

•

Faulty cord and plug

•

Check cord and plug and
power at wall receptacle

•

Faulty drain switch

•

Check drain switch per
Drain Switch Section

•

Faulty PC board

•

Remove and replace control
panel

•

Faulty high limit control switch

•

Check high limit control
switch per High Temperature Limit
Section

•

Drain valve open

•

Close drain valve

•

Possible faulty gas control

•

With power removed from

valve

fryer, check across electrical
leads of gas valve
with multimeter, and gas
valve on ON position

•

Possible faulty temperature probe

•

Replace temperature probe

•

Bad spark ignitor

•

Replace spark ignitor

•

Low air pressure

•

Clean or replace blower

•

Replace air pressure switch

•

Faulty ignitor module

•

Replace ignitor module

• Spark ignitor or flame sensor out of

• The spark ignitor needs to be 1/8 in.

adjustment

from the pilot hood, and the
flame sensor, 1/4 in

Shortening will not heat

305

1-7