POWER SUPPLY CONNECTION

The pressure washer is factory-equipped with an electrical

cord and a ground fault circuit interrupter (GFCI) plug

(Fig.14). This cord should only be connected to an electrical

outlet installed in accordance with local safety regulations.
NOTE:

The power supply must be 120V, 60hz and a

minimum 15 amp dedicated circuit.

WARNING:

Test GFCI before each

use. DO NOT use pressure washer if

test below fails.

WARNING

ATTENTION:
Proper water connection

(Fig.11).

4.1

HIGH PRESSURE HOSE

Remove and discard the water plug. (Fig.9)

Attach the high pressure hose by carefully inserting the

fitting with the o-ring into the high pressure outlet and

tighten the threaded nut by hand. (Fig.10)

4.2 WATER

CONNECTION

(Cold

water)

Before connecting, run water through the garden hose

(not supplied) to flush out any foreign matter. Attach

garden hose to the pressure washer water inlet con-

nection. (Fig. 11) Page 9.

If your water source is a Well, the garden hose length

can only be 30 ft. (9m) max.

4.0

OPERATING CONNECTIONS

(See

pages

9-11)

GFCI Test Procedures (Fig.14):
1. Plug GFCI into power receptacle. Indicator should

turn red.

2. Press Test button. Red indicator should disap-

pear.

3. Press Reset button for use. When released, red

indicator will reappear.

Do not use if above test fails.

NOTE:

The GFCI must be reset each time the pressure

washer is connected to an electrical outlet. Reset by simply

pushing the reset button on the GFCI power plug.

A. Connect only to properly grounded

outlet.
B. Inspect cord before using. Do not use

if cord is damaged.

C. Keep all connections dry and off the ground.
D. Do not touch plug with wet hands.
E. The pressure washer is provided with a ground-fault

circuit interrupter built into the power plug.

If replacement of the plug or cord is needed, use

only identical replacement parts. Contact Customer

Service at www.huskypowerwasher.com for proper

replacement parts.

WARNING

When using an extension cord, observe the specifi-

cation below:
Cable Length

Wire Gauge

Up to 25 ft.

12 AWG Outdoor

WARNING:

To reduce the risk of

electrocution, keep all connections dry

and off the ground. Do not touch plug

with wet hands.

A. Inspect cord before using. Do not use

if cord is damaged.
B. Keep all connections dry and off the

ground.
C. Do not touch plug with wet hands.

GROUND-FAULT CIRCUIT-INTERRUPTER PRO-
TECTION

A. Connect to only a properly grounded GFCI

circuit.

B. This pressure washer is provided with a ground-

fault circuit-interrupter (GFCI) built into the plug

of the power-supply cord. This device provides

additional protection from the risk of electric shock.

Should replacement of the plug or cord become

necessary , use only identical replacement parts

that include GFCI protection.

WARNING

WARNING

EXTENSION CORDS
Use only extension cords that are intended for outdoor

use. These extension cords are identified by a marking

“Acceptable for use with outdoor appliances: store indoors

while not in use”. Use only extension cords having an

electrical rating not less than the rating of the product.

Do not use damaged extension cords.

Examine extension cord before using and replace if

damaged.

Do not abuse extension cord and do not pull on any cord

to disconnect.

Keep cord away from heat and sharp edges. Always

disconnect the product from the extension cord.

WARNING:

Do not pull on any

cord to move unit from one location to

another.

WARNING