OM-185 480 Page 9

SECTION 4 – MAINTENANCE & TROUBLESHOOTING

Y

Disconnect power
before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace Damaged

Gas Hose

Clean

And

Tighten

Weld

Terminals

Replace

Damaged Or

Unreadable

Labels

Repair Or Replace

Cracked Cables

And Cords

6 Months

Blow Out Or

Vacuum Inside

4-1.

Overload Protection

Ref. ST-144 451-D / Ref. ST-800 185-A

If fuse F1 opens, the weld control
shuts down. To check or change
F1, proceed as follows:

1

Fuse Holder Cover

2

Fuse (See Parts List For
Fuse Size)

1

2

Push And Turn

Pull Out And

Replace F1

Push And Turn