OM-185 480 Page 7

2-5.

Input Power Connection

ST-801 839

1

Contact Closure
Interconnecting Cord And
Plug PLG5

2

Voltage Sensing Lead

Connect to workpiece for CC op-
eration (see Section 2-3).

3

Grounded Receptacle

A 15 ampere branch circuit pro-
tected by time-delay fuses or cir-
cuit breakers is required.

4

Input Power Cord And Plug
PLG4

Connect input power plug to a
proper receptacle.

1

3

4

2

2-6.

Contact Closure Connections

A. 5-Pin Plug Information For Standard Contact Closure Connections

Pin*

Pin Information

E

D

A

A

Contact output signal.

D

A

C

B

B

Input control to energize weld contactor. Contact closure to A completes 24 volts ac contactor
control circuit.

*The remaining pins are not used.