Hoshizaki REFRIGERATED PREP TABLE WITH RAISED RAIL 73168 User Manual

Page 35

Advertising
background image

35

Problem

Possible Cause

Remedy

[1] Cabinet

temperature too
high. (continued)

g) Defrost

1. Defrost time

insufficient to remove
frost. Operation in
humid conditions.

1. See "4. Cabinet Defrost."

2. Incomplete defrost.

2. See "4. Cabinet Defrost."

h) Air Filter or Condenser 1. Clogged, dirty.

1. Clean.

i) Cabinet Fan Motor

1. Defective.

1. Check and replace.

j) Cabinet Liquid Line

Valve

1. Does not open.

1. Check and replace.

k) Service Valve(s)

1. Partially or completely

closed.

1. Confirm service valve is

open.

l) Refrigerant

1. Leak.

1. Recover, repair leak,

replace drier, evacuate, and
recharge.

m) Expansion Valve

1. Operating erratically.

1. Check and replace.

n) Compressor

1. Defective.

1. See "1.[3] Compressor will

not start or stops operating."

o) Control Board

1. Defective.

1. Replace.

[2] Cabinet temperature

too low.

a) Setpoint and/or

Temperature
Correction Factor

1. Incorrect.

1. Correct setting(s).

See "II.D.4.c) Temperature
Setpoint" or
"II.D.4.f) Temperature
Correction Factor" for
defaults.

b) Frozen Food

1. Frozen food recently

placed in refrigerator.

1. Allow time for unit to return

to setpoint temperature.

c) Cabinet Thermistor

1. Defective.

1. Check and replace.

d) Cabinet Liquid Line

Valve

1. Does not close.

1. Check and replace.

e) Compressor Relay

1. Defective; contacts

welded.

1. Replace.

f) Control Board

1. In alarm or defective. 1. See "III.A Alarm Signals" or

replace.