HE365A,B POWERED FLOW-THROUGH HUMIDIFIER

68-0243

3

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow them

could damage the product or cause a hazardous
condition.

2. Check the ratings given in the instructions and on the

product to make sure the product is suitable for your
application.

3. Installer must be a trained, experienced service

technician.

4. After installation is complete, check out product

operation as provided in these instructions.

CAUTION

Personal Injury or Equipment Hazard.
Improper drilling can cause equipment damage or
personal injury.
Do not cut or drill into any air conditioning or electrical
accessory.

CAUTION

Property or Equipment Hazard.
Can cause property or equipment damage.

Locate the humidifier where the ambient
temperature is between 32

°

F (0

°

C) and 160

°

F

(71

°

C).

Do not install where freezing temperatures could
occur.

Be sure supply plenum static pressure is no
greater than 0.4 in. wc and water pressure is no
greater than 125 psi.

Location and Mounting

IMPORTANT

Mount the humidifier at least 3 in. (76 mm) above
the furnace jacket to allow adequate space for the
drain line. Check that there is adequate space above
the humidifier to remove and install the humidifier
cover. Do not install on a furnace jacket.

1. Determine the best location for the humidifier and draw

a level line on the plenum. See Fig. 2 and 3.

IMPORTANT

Be sure the template is level before marking to
assure optimal product performance.

2. Tape the template in position and trace around the

template.

3. Remove the template and carefully cut the rectangular

opening.

4. Loosen the thumbscrew on the bottom of the humidifier

and remove the cover.

5. Remove the humidifier pad assembly by grasping the

top of the tray and pulling the assembly out of the
housing. See Fig. 4.

6. Position the securing clips as shown in Fig. 5. Do not

completely seat them.

Fig. 2. Typical humidifier installation locations.

Fig. 3. HE365 Humidifier location in relation to air

conditioning cooling coils.

Fig. 4. Humidifier components.

M12808A

HORIZONTAL

DO

WN

FL

O

LO

WB

OY

RE

TU

RN

RE

TU

RN

RETURN

HIGHBOY

RE

TU

RN

M12812A

M14671

COVER
ASSEMBLY

HUMIDIFIER
PAD ASSEMBLY

FEED TUBE NOZZLE

WATER
DISTRIBUTION TRAY

HUMIDIFIER
HOUSING

THUMB
SCREW

Advertising