B. Clearances

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specified in Fig-

ure 6.2.

DO NOT pack required air spaces with insulation or other materials.

Heatilator • I100 • 35144 • Rev AG 7/12

Figure 6.2 Air Space Clearances

0 in.

from floor

Attic

Insulation

Shield

Ceiling Firestop

(ceiling)

(roof)

(attic)

(ceiling)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

2 in. min.

(51 mm)

Must have 2 in. (51 mm)

minimum clearance

to header

Ceiling Firestop

Offset/Return with

hanger straps

Storm Collar

Roof Flashing

0 in. to level

of standoffs

1-1/2 in. (38mm) from

side of appliance

(except at nailing flanges

where it is 1/2 in. (13 mm)

1-1/2 in. (38mm) from

back of appliance