Grid represents inch scale – Hearth and Home Technologies I100 User Manual

Page 20

Advertising
background image

20

60 5/8 in.

[1540 mm]

50 in.

[1270 mm]

24 in.

[610 mm]

19 3/4 in.

[502 mm]

24 in.

[610 mm]

22 3/8 in.

[568 mm]

FLUSH

FRONT

4 in.

[102 mm]

BRICK

FRONT

50° angle

39° angle

Grid represents

inch scale.

D. Frame the Fireplace

Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
• Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.

• Framing across the top of fireplace must be above top standoffs.

Fireplace header cannot

be positioned until after

the fireplace assembly is

in place.

Use only non-combustible

material below the top of

the front standoffs.

Framing must be

extended straight up, all

the way to the ceiling.

2 in. (51 mm)

minimum air

space clearance

to the enclosure.

30 1/2 in.*

(772 mm)

61 5/8 in.

(1565 mm)

8 in. (203 mm) extra space

needed (both sides) for outside air

connection. If outside air duct has

no bend, this dimension may be

reduced as long as minimum

clearances are met.

* If interior of chase will be

drywalled, add the thick-

ness to this measurement.

Figure 6.4 Framing the Fireplace

C. Sidewalls/Surrounds

• Adjacent combustible sidewalls must be located a minimum of 24 in. (610 mm) from the fireplace opening.

• Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed within the gridded area,

Figure 6.3.

Figure 6.3 Mantel Leg or Wall Projections (Acceptable on both sides of opening)

Heatilator • I100 • 35144 • Rev AG 7/12

Advertising