Quadra-Fire • Columbia Bay • 250-5195 Rev. K

INCLUDED IN KIT: Blower; 2 female spade wire connec-
tors.

Turn off power supply.

Remove blower housing from appliance, if necessary.

Disassemble housing if needed, retaining all fasteners, and
remove the blower.

Reassemble blower in housing using fasteners previously
removed.

Reinstall blower housing to appliance.

Turn power supply back on.

Blower motor comes standard with 2 male spade wire
connectors. If your appliance has a different connec-
tion, use the two female spade wire connectors provided
to modify the appliance wiring harness.

H. Blower Installation

T

OOLS REQUIRED: Phillips head screwdriver.

Figure 8.12 Blower Wiring Diagram

BLACK

F

M

F

F

Snap Disk

Fan Assembly

GRN

WHITE

BLACK

F

M F

M

WHITE

Fan Speed

Control

BLACK

Strain Relief Bushing

Power Cord (110 VAC)

Ground

WHITE

BLACK

F = Female
M = Male

BLACK

BLACK

BLACK

Advertising