HP Triplex Ceramic Plunger Pump LP400 User Manual

Page 10

Advertising
background image

10

9) Remove seal case (37) from

seal sleeve (35).

10) Check plunger surface (25

and 29B) for wear and pit-
ting. If none is found, pro-
ceed to step twelve.

11) If plunger (29B) is worn, re-

move tension screw (29C)
with a 17mm wrench. Clean
tension screw with wire
brush to remove any old
locktite. Discard copper gas-
ket (29D) and replace with
new. Clean the front surface
of plunger/ crosshead as-
sembly (25). Install new
plunger (29B) onto plunger/
crosshead assembly. Put
some locktite on both sur-
faces of copper gasket and
tension screw threads. Se-
cure plunger in place with
tension screw and gasket
and tighten to 33 ft.-lbs.

REPAIR INSTRUCTION - LP350, LP400, LP450

12) Remove v-sleeves (40) and support ring (41) for seal case (37)

and replace with new elastomers. Lubricate parts before
reinstalling into seal sleeve. Replace seal sleeve/seal case
assembly (35/37) into the valve casing (43).

35

39

40 (2)

41

42 38 38A

37

38

(LP400 only)

13) Place entire manifold assem-

bly sleeve assembly over the
studs (49) and push firmly
until seated against the crank-
case (1).

14) Replace nuts and washers
(49A, B) and tighten to 59 ft.-lbs.
in the pattern as shown to the
right.

6

4

2

7

8

1

3

5