5 – maintenance &troubleshooting, 1. routine maintenance, 2. overload protection – Hobart Welding Products 150 User Manual

Page 25

Advertising
background image

OM-210 088 Page 21

SECTION 5 – MAINTENANCE &TROUBLESHOOTING

5-1.

Routine Maintenance

Y

Disconnect power before maintaining.

3 Months

Replace
unreadable
labels.

Repair or
replace
cracked
weld cable.

Clean and
tighten weld
terminals.

6 Months

Blow out or
vacuum inside.
During heavy
service, clean
monthly.

Or

5-2.

Overload Protection

Ref. ST-802 081

1

Circuit Breaker CB

Circuit breaker CB protects wire
feed motor from overload. If circuit
breaker opens, wire stops feeding.

2

Circuit Breaker CB1 (CSA
Model)

CB1 protects unit from overload. If
CB1 opens, unit shuts down.

3

Circuit Breaker CB2 (CSA
Model)

Circuit breaker CB2 protects wire
feed motor from overload. If circuit
breaker opens, wire stops feeding.

Reset breaker.

1

2

3

120 VAC (CSA) Model

120 VAC And 230 VAC (CSA) Models

Advertising
This manual is related to the following products:

120