Step 9 wiring the fireplace, For standing pilot ignition wiring, Caution – Heat & Glo Fireplace PIER-TVFL st-42tvfl User Manual

Page 18: Figure 11. standing pilot ignition wiring diagram

Advertising
background image

24

Figure 11. Standing Pilot Ignition Wiring Diagram

!

!

Step 9
Wiring the
Fireplace

NOTE: Electrical wiring must be installed by a
licensed electrician.

Caution: Disconnect remote controls if you are
absent for extended time periods. This will
prevent accidental fireplace operation.

For Standing Pilot Ignition Wiring

Appliance Requirements
This appliance DOES NOT require 110-120 VAC to

operate.

WARNING
DO NOT CONNECT 110-120 VAC TO THE
GAS CONTROL VALVE WALL SWITCH
OR THE APPLIANCE WILL
MALFUNCTION AND THE VALVE WILL
BE DESTROYED
.

Optional Accessories
Optional remote control kits require that 110-120 VAC
be wired to the factory installed junction box before the
fireplace is permanently installed.

Wall Switch
Position the wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less length
of 18 A.W.G. minimum wire and connect it to the
fireplace ON/OFF switch pigtails.

WARNING
DO NOT CONNECT 110-120 VAC TO THE
WALL SWITCH OR THE CONTROL
VALVE WILL BE DESTROYED.

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION
WHEN SERVICING CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.

HI-TEMP LIMIT SWITCH

ON

OFF

ON/OFF SWITCH

GAS VALVE

THERMOPILE

BLACK S1

OPTIONAL WALL SWITCH,

THERMOSTAT OR REMOTE

REMOTE SWITCH

PIGTAIL

BLACK L1

BLACK L2

WHITE T2

RED T1

THERMOCOUPLE

Advertising