For direct spark ignition (dsi) wiring, Caution – Heat & Glo Fireplace PIER-TVFL st-42tvfl User Manual

Page 19

Advertising
background image

25

Figure 12. Direct Spark Ignition (DSI) Wiring Diagram

For Direct Spark Ignition (DSI) Wiring

Appliance Requirements
This appliance requires that 110-120 VAC be wired
to the factory installed junction box. Maintain correct
polarity when wiring the junction box.

Optional Accessories
Optional remote control kits require that 110-120
VAC be wired to the fireplace junction box.

Wall Switch
Position the wall switch in the desired position on a
wall. Run a maximum of 25 feet (7.8 m) or less of
16 A.W.G. minimum wire and connect it to the
fireplace ON/OFF switch pigtails.

CAUTION

LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN CAUSE
IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER
SERVICING.

FLAME SENSOR/SPARKER

IGNITION
MODULE

GAS

VALVE

HI-TEMP

LIMIT SWITCH

ON/OFF SWITCH

REMOTE OUTLET

FAN OUTLET

CONNECTORS

HOT

GROUND

NEUTRAL

HI TEMP

LIMIT SWITCH

OPTIONAL REMOTE,

WALL SWITCH

OR THERMOSTAT

(ON CERTIFIED UNITS ONLY)

BLACK

GROUND

FAN

REM

OPTIONAL

FAN

SWITCHES

L2

(NEUTRAL)

L1

(HOT)

100-254A

JUNCTION

BOX

120 VAC

ON/OFF

GROUND

TO

FIREPLACE

CHASSIS

WHITE

GREEN

BLUE

501-592

DSI

MODULE

O

R

A

N

G

E

459-591

IGNITOR

476-500

DSI CONTROL VALVE

WHITE

BLACK

WHITE

YELLOW

BLUE

Advertising