Tld series, Options, Flow-through/output signal 4 ma to 20 ma – Honeywell Switches and Sensors User Manual

Page 142: Flow-through/output signal 0 vdc to 5.0 vdc, Single port/output signal 4 ma to 20 ma

Advertising
background image

140

www.honeywell.com/sensing

PRESSURE SENSORS

TLD Series

OPTIONS

Flow-through/Output Signal 4 mA to 20 mA

MEASUREMENT TYPE

PRESSURE RANGE

CONNECTIONS

REFERENCE

Compound

-14.7 psig to 100 psig

1/4 in. OD 0.035 in. wall, 1/4 in long tube stub

TLDF4CVT4V100CP

Compound

-14.7 psig to 100 psig

1/4 in. female face seal, swivel

TLDF4CVVFV100CP

Compound

-14.7 psig to 100 psig

1/4 in. female face seal, swivel

TLDF4BSVFV100CP

Flow-through/Output Signal 0 Vdc to 5.0 Vdc

MEASUREMENT TYPE

PRESSURE RANGE

CONNECTIONS

REFERENCE

Compound

-14.7 psig to 100 psig

1/4 in. OD 0.035 in. wall, 1/4 in long tube stub

TLDF5CVT4V100CP

Single Port/Output Signal 4 mA to 20 mA

MEASUREMENT TYPE

PRESSURE RANGE

REFERENCE

Compound

-14.7 psig to 100 psig

1/4 in. female face seal, swivel

TLDS4BNVFV100CP

Flow-through display orientation and transducer location

z

s

72,4
2.85

38,1
1.50

35,9
1.42

26,1
1.03

CABLE
2 COND
1,8 m (6 ft)

38,1
1.50

82,5
3.25

z

s

38,1
1.50

38,1
1.50

z

s

38,1
1.50

38,1
1.50

72,4
2.85

38,1
1.50

CABLE
2 COND
1,8 m (6 ft)

z

s

38,1
1.50

82,5
3.25

26,1
1.03

35,9
1.42

77,0
3.03

42,7
1.68

CABLE
2 COND
1,8 m (6 ft)

BF - Transducer at bottom, front display orientation

BS - Transducer at bottom, side display orientation

CV - Transducer at center back,
vertical display orientation

CH - Transducer at center back,
horizontal display orientation

With space at a premium in semiconductor gas distribution systems, the Series TLD pressure transducer with local
display offers an integrated solution that reduces the overall height of the transducer/display assembly to as little as 3.5
in [88,9 mm]. To accomplish this, the transducer’s signal amplifier is mounted within the display, with the added benefit
of zero and span adjustments conveniently located on the LED display face.

Supply voltage:

12.0 Vdc to 30.0 Vdc

Signal conditioning:

Amplified compensated

Operating temperature range:

-40 °C to 85 °C (-40 °F to 185 °F)

Compensated temperature range:

0 °C to 70 °C (32 °F to 158 °F)

Termination type:

1,83 m (6 ft) 2-conductor cable

Advertising