Input n:clock[:source – HP E1459A User Manual

Page 48

Advertising
background image

HP E1459A SCPI Command Reference

47

INPut

n:CLOCk[:SOURce]?

Returns the programmed value of the input clock source for Port n.

Parameters

Comments

The value returned is an unquoted string of

EXT

or

INT

.

Example

INPut2:CLOCk[:SOURce]?

queries the input clock source for Port 2.

INPut

n:DEBounce:TIME <time> | MINimum | MAXimum | DEFault

Programs the input debounce time for Port n. Ports 0 and 1 share the same debounce
circuitry; Ports 2 and 3 share the same debounce circuitry.

Parameters

Comments

The available debounce times are:

18.0

µ

S, 36

µ

S, 72

µ

S, 144

µ

S, 288

µ

S, 576

µ

S, 1.13 mS, 2.26 mS, 4.6 mS, 9.2

mS, 18.4 mS, 36.9 mS, 73.8 mS, 148.0 mS, 294.0 mS, 590.0 mS, 1.18 S, 2.36
S, 4.72 S, 9.43 S, 18.9 S, 37.8 S, 75.0 S, 150.0 S, 300 S, 600 S, 1200 S, 2400 S,
4800 S, 9600 S. Any value sent other than those listed is rounded to the nearest
discrete value.

Debounce time is rounded to the nearest discrete value. For example 16.0

µ

S to

18.4

µ

S is rounded to 18

µ

S, 18.5

µ

S to 36.4

µ

S is rounded to 36

µ

S, 36.5

µ

S

to 72.4

µ

S is rounded to 72

µ

S, etc.

Ports 0 and 1 use the same debounce time, Ports 2 and 3 use the same debounce

time. For n = 0 or n = 1, both Ports 0 and 1 are set; for n = 2 or n = 3, both Ports
2 and 3 are set.

*RST Condition: sets the value for the debounce time to 18.0

µ

Sec for all four

Ports.

Parameter Name

Parameter Type

Range of Values

Default

INPut

n

numeric

0, 1, 2, 3

0

Parameter Name

Parameter Type

Range of Values

Default

INPut

n

<time>

DEFault

MINimum

MAXimum

numeric

numeric (floating pt)

0, 1, 2, 3

18.0

µ

Sec through 9600 Sec

Default 18.0

µ

Sec

Minimum 18.0

µ

Sec

Maximum 9600 Sec

0

18.0

µ

Sec

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com