Hitachi HUS103036FL3800 User Manual

Page 19

Advertising
background image

Drawing No. Sheet No. Revision

K6610091

19/43 2005/2/23


5.2 Low voltage differential (LVD) mode

The NW and NC drives have two different transceivers to allow customer to use it
in traditional systems which may use single-ended drivers and receivers, or to use
it in low voltage differential (LVD) systems which use LVD drivers and receivers.
Their I/O circuits are selectable using the I/O "DIFFSENS" line. When the I/O
"DIFFSENS" line is between -0.35V and +0.5V, the drive interface circuits operate
single-ended. When "DIFFSENS" is between +0.7V and +1.9V, the drive interface
circuits operate LVD.
Customer can configure the drive to switch between single-ended and LVD modes
using the I/O "DIFFSENS" line, or force it to operate in single-ended mode only as
described later in this document.

Note 1: To operate at LVD mode, all devices on the same bus must be running in LVD

mode. If you add any single-ended device to a bus that is operating in LVD
mode, all devices drop back to operating in single-ended mode. This eliminates
the possibility of reaching Ultra-2 SCSI transfer rates.

Note 2: Do not mix LVD drives on the same daisy chain with devices having high

voltage differential (HVD) interface circuits.

Advertising