INSTALLATION INSTRUCTIONS

69-0265ES

CT50A, CT51A, CT53A

Thermostats

CT51A

CT50A Heating only
Compatible with most 2 wire gas and oil heating systems.

CT51A Heating/Cooling
Compatible with most 4 wire gas and oil heating systems
and electric heat. Will not work on Heat Pump systems.

CT53A Millivolt heating only
For 250, 500, 750 millivolt systems.

PREPARATION FOR INSTALLATION

Assemble tools required; screwdriver, level, wire stripper.

REMOVING OLD THERMOSTAT

!

Begin by turning off power to the heating system at
the main fuse panel. Most residential systems have a
separate switch box or circuit breaker for
disconnecting power to the furnace.

!

Remove cover of old thermostat. Cover normally
snaps off when pulled firmly from the bottom. If it
resists, check for a screw that locks the cover on.

MERCURY NOTICE

If this product is replacing a control that contains
mercury in a sealed tube, do not place the old
control in the trash. Contact your local waste
management authority for instructions regarding
recycling and proper disposal.

For CT50A, CT51A Installation

!

Before removing the old thermostat from the wall, look
at it carefully to locate the heat anticipator adjustment
mechanism. See illustration below to help you
recognize the heat anticipator. Make a note
here _____ of the anticipator setting.

IMPORTANT

Setting the heat anticipator allows the thermo-
stat to maintain accurate temperature control.

MOUNTING CLIPS
(FOR COVER)

MOUNTING CLIPS
(FOR COVER)

TOP MOUNTING
HOLE

ADJUSTABLE HEAT
ANTICIPATOR
SETTING LEVER
(CT50A, CT51A ONLY)

FAN SWITCH
(CT51A ONLY)

SYSTEM SWITCH
(CT51A ONLY)

BOTTOM
MOUNTING HOLE

TEMPERATURE
SETTING LEVER

M11901