Optional blower, Installation of optional blower – Heat & Glo Fireplace WS-250 User Manual

Page 17

Advertising
background image

17

Part #831-1700
The blower is shipped fully assembled and

ready for installation.
1. Using three 1/4-20 bolts supplied, attach

blower to lower rear of stove, as shown.

2. Plug blower cord into a grounded outlet.

Do not remove ground prong from plug.

Route power cord to avoid heat from the

stove, or other damage.

3. Adjust the blower speed control to the

desired speed.

BLOWER SWITCH ADJUSTMENTS
The blower speed control for this unit is ad-

justed at the factory, and should not require

further adjustment. When the speed control

is turned clockwise, it will click on to high

FIGURE 21

3. Medium burn setting: The blower should be left

off until a good burn is established, then turned

on at a medium or high rate.

4. Low burn setting: The blower tends to cool off

the stove. If you are using wet wood or a very low

burn setting, leave blower off until the burn is well

established. Then, if you wish, turn the blower on

at a lower rate. Too high a blower setting with a

low burn rate may adversely affect emissions.

5. The blower is equipped with a speed control. The

highest blower speed is obtained by turning the

speed control on and then adjusting back towards

off as far as possible without turning the blower

off. For a low blower speed, turn the control knob

clockwise as far as possible.

speed. Turn the speed control clockwise to decrease

the speed. At full clockwise, the blower should blow

gently, but should not stop.
STEPS FOR ADJUSTING THE BLOWER

SPEED CONTROL
1. With the unit plugged in, turn the speed control

knob to slow (full clockwise).

2. With a small screwdriver, adjust the blower

speed by turning the adjustment mechanism

through the hole on the side of the speed control.

3. Adjust the speed so the blower runs slowly, but

does not stop. Turn clockwise to slow the blower

and counterclockwise to increase the speed.

BLOWER OPERATING INSTRUCTIONS
If your wood stove is equipped with an optional blower,

you should follow these guidelines:
1. Initial (cold) start-up: Leave blower off until your

stove is hot and a good coalbed is established.

The blower may be turned on approximately 30

minutes after loading the stove with fuel.

2. High burn setting: The blower may be left on

throughout the burn.

INSTALLATION OF OPTIONAL BLOWER

Advertising