FIGURE 5. Clearance to Combustibles (UL AND ULC)

CLEARANCES TO COMBUSTIBLES

Floor protector must be 3/8” (10mm) thick minimum

noncombustible material or equivalent, extending

beneath heater and to the front/sides/rear as indicated

in the ‘‘Floor Protection’ (See Figure 5).

Note 1: 6" (152mm) diameter single wall, minimum

24 MSG black or blued steel connector pipe with a

listed factory-built type HT chimney suitable for use

with solid fuels or a masonry chimney.
Note 2: 6" (152mm) diameter double wall air cooled

connector pipe with listed factory-built type HT chim-

ney or a masonry chimney. (Mobile home venting sys-

tem must be equipped with a rain cap and spark ar-

restor.) For installations with a preexisting class A

chimney system, a listed stainless steel chimney liner

should be installed, or the existing chimney exam-

ined by a chimney sweep for acceptable further use.
Note 3: Alcove specifications: Maximum depth of al-

cove shall be no more than 48" (1219mm). For addi-

tional alcove information and clearances, refer to

clearances to combustibles above.
NOTE: Unit is approved for use with listed double wall

air-insulated chimney connector or elbows.

When locating your stove consider safety, conve-

nience, traffic flow, and the fact that the stove will need

a chimney and chimney connector.
NFPA 211: Use a noncombustible material with 1”

(25mm) ventilated air space to reduce clearances.

However, this is not to exceed 50% of WS-150’s (or

WS-250’s) specified clearances.
NOTE: Must follow NFPA 211 spacing and materials

to qualify. It is also subject to local jurisdiction.
AVOID FIRE: Maintain the designated clearances to

combustibles. Insulation must not touch the chimney.

You must maintain the designated air space clear-

ance around the chimney. This space around a chim-

ney is necessary to allow natural heat removal from

the area. Insulation in this space will cause a heat

buildup, which may ignite wood framing.

Minimum clearances to Combustible Materials

(in inches and millimeters)

Chimney &

Installation

Clearance

Connector

A

B

C

D

E

F

Residential

Standard

Note 1

14"

26"

18"

12"

18"

10"

(356)

(661)

(457)

(305)

(457)

(254)

Residential/

Reduced

Note 2

12"

26"

16"

10"

18"

8"

Mobile Home

(305)

(661)

(406)

(254)

(457)

(203)

Alcove

Standard

Note 2 & 3

12"

26"

N/A

10"

18"

8"

(305)

(661)

N/A

(254)

(457)

(203)