9

A chimney inside the house must have at least 2"

(50mm) of clearance to the combustible structure.

A chimney outside the house must have at least 1"

(25mm) clearance to the combustible structure.

Firestops must be installed in the spaces where

the chimney passes through floors and/or ceiling

(Figure 8).

FIGURE 8

Minimum 1”

Clearance for

Exterior Chimney

to Sheathing

Remember that insulation must not contact the

chimney. There must be air space around the

chimney. Insulation must be 2" (50mm) or more from

the chimney (Figure 9).

A chimney must be the required height above the

roof or other obstruction for safety and proper draft

operation. The chimney must be a minimum of 3'

(914mm) higher than the highest point where it

passes through the roof, and at least 2' (610mm)

higher than the highest part of the roof or structure

that is within 10' (3048mm) of the chimney, mea-

sured horizontally (Figure 10).