Minimum 3 ½" (89mm) [4" (102mm) nominal] thick

solid bricks are to be used. The fire clay liner (ASTM

C35 or equivalent), 5/8" (16mm) wall thickness, must

not penetrate into the chimney beyond the inner

surface of the chimney flue liner and must be firmly

cemented in place. If it is necessary to cut a hole in

the chimney liner, use extreme care to keep it from

shattering. Refractory mortar must be used at the

junction with the chimney liner. After the assembly is

complete, insert the chimney connector into the fire

clay liner. Do not push it beyond the inside edge of

the chimney liner, as this will affect the draw of the

chimney.

B. 6" SOLID PACK CHIMNEY WITH METAL

SUPPORTS AS A THIMBLE:

For the method of installation to a masonry chimney

shown in Figures 13 and 14 , it will be necessary to

purchase a 6" (152mm) inside diameter, 12" (305mm)

long section of prefabricated listed solid pack chim-

INSTALLATION USING MASONRY

OR BRICK CHIMNEY

FIGURE 12

ney to use as a thimble. Purchase a wall

spacer, trim collar and wall band that

are manufactured to fit the chimney

section you purchase. Cut out a 14 ½"

(368mm) diameter opening in the wall.

It may be necessary to cut wall studs

and install a header and sill frame to

maintain the wall support. The hole in

the chimney must have at least a 6"

(152mm) diameter fire clay liner or

equivalent, secured with refractory mor-

tar. If it is necessary to cut a hole in the

chimney liner, use extreme care to keep

it from shattering.
The safety features of this system are

the 2" (50mm) air space between the

chimney section and combustible wall

and the 1" (25mm) air space around the

chimney connector as it passes through

the chimney section to the chimney. The

location of the opening through the wall

to the chimney must leave a minimum

18" (457mm) vertical clearance be-

tween the connector pipe and the ceil-

ing, to prevent the ceiling from catching

fire when using single wall pipe.
First, build the frame for the thimble,

making sure that it is no smaller than

14½" (368mm) diameter, which will

maintain a 2" (50mm) air space around

the chimney section. Attach the wall

spacer to the chimney side of the frame. Then insert

the frame into the opening, toe-nailing it to the wall

studs. Install the wall band in the framing to secure

the chimney section in place. Insert a single section

of chimney connector into the chimney through the

wall band, being sure it does not protrude into the

chimney beyond the edge of the chimney flue lining.
Apply high temperature furnace cement to the end of

the chimney section and install it over the connector,

through the wall band, and through the wall spacer.

Tighten the wall band to hold the chimney section firmly

in place and against the chimney. Install the trim col-

lar on the outside of the opening.
Check to insure there is a 1" (25mm) air space be-

tween the connector and the chimney section. Also,

during installation, always check to insure that a 2"

(50mm) air space is being maintained to the wood

framing. Do not fill this space with insulation. Insula-

tion in this air space will cause a heat buildup which

may ignite the wood framing.