Hose Break-In Procedure

1 Make sure fluid flow

regulator (K) is turned all
the way down.

2 Pour approxi-

mately 1 gallon
hot water in
sprayer hopper
to lubricate the
pump.

3 Turn power switch (A) on.

4 Hold in prime switch (P).

5 Turn fluid flow regulator

(K) up to full pressure.

6 Run sprayer dry for 1 to 1-1/2 minutes.

ti4303a

K

ti4301a

WATER

ti4653a

ti4364a

P

K

ti4655a