Preparation, Pressure relief procedure, Grounding and electric requirements – Healthyway 310645H User Manual

Page 7

Advertising
background image

Preparation

310645H

7

Preparation

Pressure Relief Procedure

1 Turn Main Power Switch

(A) OFF.

2 Turn fluid flow regulator

(K) all the way down to
reduce pressure.

3 Open gun air valve (aa).

4 Trigger gun, spraying

material back into
hopper (C).

Grounding and Electric Requirements

The sprayer must be grounded. Grounding reduces the
risk of electrical shock by providing an escape wire for
the electrical current.

• The sprayer cord includes a

grounding wire with an appro-
priate grounding prong.

• The plug must be plugged into

an outlet that is properly
installed and grounded in
accordance with all local codes
and ordinances.

• Do not modify plug! If it will not

fit in outlet, have grounded out-
let installed by a qualified elec-
trician.

• Sprayer model electric require-

ments are provided on page 2.

Extension Cords

• Only use an extension cord with

an undamaged 3-prong plug.

• For up to 100 ft (30.48 m) cord,

use 3-wire, 12 AWG (2.5 mm

2

)

minimum.

ti4292a

ti4303a

K

ti4000a

A

ti4294a

WARNING

Read warnings, page 3.

Ground

ti4295a

ti4296a

ti4297a

Ground

ti4295a