Relief Valve and Flow Sensor Manifold

310645H

25

Relief Valve and Flow Sensor Manifold

For 120 V sprayer use Relief Valve Replacement Kit
287325.

For 230 V sprayer use Relief Valve Replacement Kit
287350.

Disassembly

First read and follow instructions in the Before
performing any service on sprayer
section, page 9.

Then remove hopper, front and back covers, page 9.

1 Remove air line to

regulator.

2 Remove air line from

cooler to manifold.

3 Disconnect wires to Relief Valve. Pay attention to their

location to insure they are reattached correctly.

4 Remove 2 nuts securing

Relief Valve to sprayer.

5 Remove Relief Valve

from sprayer frame.

Reassembly

1 Position new relief valve from Kit in back of sprayer.

2 Replace and tighten screws.

3 Reattach wires to Relief Valve.

4 Reattach air line from cooler to manifold.

5 Reattach air line to regulator.Replace RotoFlex HD

Pump and hose extension, page 12.

6 Replace front cover and hopper. See Removing and

Replacing Hopper, Front and Back Cover, page 9.

ti4423a

ti4418a

ti4419a