Air Flow Sensor Replacement

26

310645H

Air Flow Sensor Replacement

For 120 V sprayer use Sensor Replacement Kit 287326.

For 230 V sprayer use Sensor Replacement Kit 287345.

Disassembly

First read and follow instructions in the Before
performing any service on sprayer
section, page 9.

Then remove hopper, front and back covers, page 9.

Remove hose extension and RotoFlex HD Pump
assembly from frame, page 11.

1 Disconnect all

wire
connections.

2 Rotate coun-

ter-clockwise to
remove sensor
from manifold.

Reassembly

1 Rotate new sensor

from kit clockwise, all
the way into opening
in Relief Valve
housing. Lightly
tighten nut.

2 Reconnect all wires.

3 Replace RotoFlex HD

Pump and hose exten-
sion, page 12.

4 Replace back and front

covers and hopper.
See Removing and
Replacing Hopper,
Front and Back Cover,
page 9.

If you are just replacing the sensor, you do not
have to remove the motor first.