Service settings, cont, Operating modes – Hague Quality Water Intl WATERMAX 60 SERIES User Manual

Page 18

Advertising
background image

WaterMax 60 Series Owner’s Manual

11/10/2008

18

Service Settings, Cont.

Operating Modes

The controller has a Timer mode (Mode 1 Frequency and Mode 1 Days of the Week), a Demand Delayed mode
(Mode 2), and a Demand Immediate mode (Mode 3). These modes are equipped with Capacity Guard

®

, which

ensures that a supply of conditioned water will be available even with excessive water usage.

Mode 1—Timer Mode

When the appliance is in Mode 1 Frequency, it will regenerate based on the frequency that is set, for example
every two days or up to every 12 days. The days between regenerations can be set. When the appliance is in
Mode 1 Days of the Week, it will regenerate on a specific day or days of the week. The display will show:

Regen SMTWTFS

Days YYYYYYY

Use the Select and Change Digit buttons to eliminate the days NOT to regenerate. The display will show the
days to regenerate.

Regen SMTWTFS
Days Y Y Y

Mode 2—Demand Delayed Mode

When the appliance is in the Patented Savematic Demand Delayed mode, it will regenerate based on the
actual water usage and the total capacity of the appliance. The time that the regeneration takes place can be
set, for example 2:00 AM. Should the total capacity be depleted before the set regeneration time, a forced
regeneration will occur.

Mode 3—Demand Immediate Mode

When the appliance is in the Demand Immediate mode, it will regenerate based on water usage alone.
Regeneration will occur when the capacity limit is reached. The time of regeneration cannot be set.

72–96 Hour Regeneration

If this value is set to Yes, the appliance will be forced to regenerate every 96 hours unless a regeneration
based on water usage occurs within the time interval. The value should always be set to Yes if iron is present in
the water.

Advertising