Troubleshooting – Hague Quality Water Intl WATERMAX 60 SERIES User Manual

Page 42

Advertising
background image

WaterMax 60 Series Owner’s Manual

11/10/2008

42

Troubleshooting

Problem

Possible Cause

Solution

No salt in brine cabinet

Add salt

Sediment in brine tank has plugged the brine
line and air check/draw tube

Remove air check/draw tube and flush with
clean water. Clean injector assembly. Clean
any sediment from brine cabinet

Flow control is plugged

Remove brine piston housing and clear debris
from the flow control

Drain line is pinched, frozen, or restricted

Straighten, thaw, or unclog the drain line

Clogged injector assembly

Remove injector cap and clean nozzle and
throat with a wooden toothpick. Replace throat
if removed

No soft water after
regeneration

Salt bridge has formed due to high humidity
or the wrong kind of salt

Test with a blunt object like a broom handle.
Push the handle into the salt to dislodge the
salt bridge

The bypass valve is in the bypass position

Place the bypass valve in the service position

Appliance is plumbed backwards

Check that appliance is plumbed correctly

Extended power outage

Reset the time of day

Water hardness has increased

Re-test the water and re-enter a new setting
number

Not metering water

Flow should be indicated with water usage. If
no flow, see below

No soft water

Blending dial is open

Make sure blending dial is closed

The bypass valve is in the bypass position

Place the bypass valve in the service position

Appliance is plumbed backwards

Check that appliance is plumbed correctly

No flow is indicated
when water is flowing

Sensor not receiving signal from magnet on
turbine

Remove sensor from bypass housing. Test
with magnet on either flat side of sensor. If
flow is indicated, check turbine. If no flow,
replace sensor

Flow indicated when
water is not being used

The household plumbing system has a leak

Repair the leak

Electric cord is unplugged

Plug in the transformer

No electric power at outlet

Check power source. Make sure outlet is not
controlled by a switch

Defective transformer

Test with volt meter for 12 VAC at control. If
less than 10 VAC or greater than 14 VAC,
replace the transformer

Defective circuit board

With 12 VAC present at controller, replace the
controller

No read-out in display

High ambient room temperature. If the
temperature exceeds 120°F, the display will
blank out. This does not affect the operation
of the controller

No action necessary