Service settings, cont, Mode 2 (demand delayed mode) setting chart – Hague Quality Water Intl WATERMAX 60 SERIES User Manual

Page 20

Advertising
background image

WaterMax 60 Series Owner’s Manual

11/10/2008

20

Service Settings, Cont.

Mode 2 (Demand Delayed Mode) Setting Chart

This section provides guidance for using different service settings to achieve the desired capacity.

Note: Mode 2 and Mode 3 have the same settings. Mode 3 is NOT recommended for residential use.

60 Series

63MAQ

1

63BEQ

1,2

63MXQ

1

63MDQ

3

62AMQ

1

62APQ

1,3,4

62AKQ

3

62AJQ

3,5

Mode 2

Yes Yes Yes No Yes No No No

Capacity

As

required

As

required

As

required

As

required

— — —

96 hour regeneration
(if iron present—yes)

6

Yes or No

Yes or No

Yes or No

Yes or No

#1 Salt Setting

Backwash 1 (minutes)

1

1

1

6

— 2

6

— — —

Brine/Rinse

(minutes) 7 7 7 — 7 — — —

Backwash 2 (minutes)

3

3

3

2

Capacity (grains) @
salt (lb)

5,900 @

1.1 lb

5,900 @

1.1 lb

8,400 @

1.6 lb

5,200 @

1 lb

— — —

#2 Salt Setting

Backwash 1 (minutes)

1

1

1

6

— 2

6

— — —

Brine/Rinse

(minutes) 12 12 19 — 12 — — —

Backwash 2 (minutes)

3

3

3

2

Capacity (grains) @
salt (lb)

16,300 @

3.2 lb

16,300 @

3.2 lb

20,000 @

4.2 lb

11,900 @

2.7 lb

— — —

#3 Salt Setting

Backwash 1 (minutes)

1

1

1

7

— 2

7

— — —

Brine/Rinse

(minutes) 30 30 47 — 30 — — —

Backwash 2 (minutes)

3

3

3

2

Capacity (grains) @
salt (lb)

26,700 @

6.2 lb

26,700 @

6.2 lb

38,700 @

9.6 lb

23,100 @

6.2 lb

— — —

#4 Salt Setting

8

Backwash 1 (minutes)

1

1

1

7

— 4

7

— — —

Brine/Rinse

(minutes) 45 45 60 — 45 — — —

Backwash 2 (minutes)

3

3

3

2

Capacity (grains) @
salt (lb)

32,500 @

9.5 lb

32,500 @

9.5 lb

49,300 @

14.4 lb

30,000 @

9.3 lb

— — —

1

Models 63MAQ, 63BEQ, 63MXQ, 62AMQ and 62APQ are certified by

WQA. All other models are not tested or certified by WQA

2

Municipally supplied chlorinated water only.

3

NA, See

Mode 1 Setting Chart.

4

Model has no backwash flow control button or retainer. Must have a

minimum of 7 gpm @ 30 psi available for proper backwash. See

Mode

1 Setting Chart.

5

Calcite will add additional hardness to water before softening.

6

If iron is present in water supply, use salt setting #3 or #4.

7

If iron is present in the water supply, set Backwash 1 to 7 minutes.

8

Do not use this salt setting in California.