B. clearances to combustibles – Harman Stove Company OAKLEAF 1-90-797000 User Manual

Page 10

Advertising
background image

10

Save These Instructions

Oakleaf Woodburning Stove

Dry Seasoned Wood Only!

3-90-798_R9

b. Clearances to Combustibles

ClearanCe to Combustibles: Vertical Venting Configuration

Location

a

unit to side Wall

17" / 432 mm

B

unit to Back Wall

14" / 356 mm

C

vent pipe to side Wall

26.75" / 679 mm

d*

vent pipe to Back Wall

*17.5" / 444 mm

CLEaRaNCE TO COMBusTIBLEs: vertical vent, Horizontal Exit

Location

a

C

B

d*

a

C

E

f

a

C

B

d

E

a

unit to side Wall

16" / 407 mm

B

unit to Back Wall

13" / 330 mm

C

vent pipe to side Wall

25.25" / 641 mm

d*

vent pipe to Back Wall

*17" / 432 mm

E*

vent pipe to Ceiling

*16" / 407 mm

f

minimum Vertical

0" / 0 mm

for clearance reduction methods, refer to nfpa 211 or local Codes

pipe clearance may be reduced using double wall

or insulated connector pipe, provided that you

adhere to the specified clearances from the stove

itself. follow pipe manufacturer's guidelines.

pipe clearance may be reduced using double wall

or insulated connector pipe, provided that you

adhere to the specified clearances from the stove

itself. follow pipe manufacturer's guidelines.

* nfpa 211 specifies 18" clearance to

single wall connector pipe. This lower

clearance is based on actual safety

test conditions.

* nfpa 211 specifies 18" clearance to

single wall connector pipe. This lower

clearance is based on actual safety

test conditions.