Dry Seasoned Wood Only!

Oakleaf Woodburning Stove

Save These Instructions

3-90-798_R9

B

a

B

a

B

a

CLEaRaNCE TO COMBusTIBLEs: Corner Installation,

vertical vent

CLEaRaNCE TO COMBusTIBLEs: Corner Installation

vertical vent, Horizontal Exit

a

shield Corner to Wall

14" / 356 mm

B

vent pipe to Wall

21.75" / 552 mm

a

shield Corner to Wall

14" / 356 mm

B

vent pipe to Wall

21.75" / 552 mm

Location

Location

ClearanCe to Combustibles: horizontal Venting Configuration

Location

a

unit to side Wall

17" / 432 mm

B

unit to Back Wall

13" / 330 mm

C

vent pipe to side Wall

26.5" / 673 mm

Corner Installation

d

shield Corner to Wall

14" / 356 mm

e

nfpa 211 specifies clearance of

18" / 457 mm

(although vent clearance may be reduced using double-wall pipe, d must be

followed)

B

a

C

E

d

*for clearance reduction methods, refer to nfpa 211 or local Codes

notiCe: when using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in

place of the existing shield.

pipe clearance may be reduced using double wall or insulat-

ed connector pipe, provided that you adhere to the specified

clearances from the stove itself. follow pipe manufacturer's

guidelines.